SRH50120






Series SRH50120

Electrical Technique Indicators

Parameters

Value

Power

Signal

Nominal Voltage

380VAC

240VAC/VDC

Insulation Resistance

≥1000MΩ/500VDC

≥500MΩ/500VDC

Conductor Size

AWG16 Tin-plated Teflon or PVC insulation wires

AWG22 Tin-plated Teflon Insulation wires

Conductor Length

Standard 300mm

Insulation strength

500VAC@50Hz,60s

 

Electrical Noise

0.01Ω


Mechanical Technique Indicators

Parameters

Value

Power

Signal

Working Speed

0-800rpm(or higher)

Working Temperature

-20-+80 or -40-+80

Working Humidity

60% RH or higher

Contact Material

Nobel Metal

Casting Material

Industrial Metal

Operating Torque

0.1N/m for 6 rings, the torque increases with each 6 rings

Protection Class

IP51

 

Specification Table 

Type

Length L

Current

Ring Number

Power(10A)

Signal(5A)

SRH50120-6P

64

6

/

6

SRH50120-12S

88

/

12

12

SRH50120-12P

88

12

/

12

SRH50120-6P/12S

112

6

12

18

SRH50120-24S

136

/

24

24

SRH50120-18P

112

18

/

18

SRH50120--12P/12S

136

12

12

24

SRH50120-6P/24S

160

6

24

30

SRH50120-36S

184

/

36

36

SRH50120-24P

136

24

/

24

SRH50120--18P/12S

160

18

12

30

SRH50120-12P/24S

184

12

24

36

SRH50120-6P/36S

208

6

36

42

SRH50120-48S

232

/

48

48

SRH50120-30P

160

30

/

30

SRH50120-24P/12S

184

24

12

36

SRH50120-18P/24S

208

18

24

42

SRH50120-12P/36S

232

12

36

48

SRH50120-6P/48S

256

6

48

54

SRH50120-60S

388

/

60

60

SRH50120-36P

184

36

/

36

SRH50120-30P/12S

208

30

12

42

SRH50120-24P/24S

232

24

24

48

SRH50120-18P/36S

256

18

36

54

SRH50120-12P/48S

280

12

48

60

SRH50120-6P/60S

304

6

60

66

SRH50120-72S

328

/

72

72




Shape dimension figure



Installation Instruction

Due to the difficulty of creating concentric installation of the rotors and stators of the slip rings, it’s advised to fix the slip rings to the rotation shaft with four fastening screws and to fix the stop plate into the stop rod. Forcible operations of the stop plate may reduce the anticipated service life of the slip rings. 


Notes

1.         The rings should bear no weights, and the conductors should bear no external forces.

2.         The conductors should be well protected to avoid damage of the insulating layer and malfunction of the product in installation.

3.         Slip rings are precision electrical equipments and should be placed in dry and dust-free environment. Precautions should be taken in harsh situations.  